Key takeaways
- The American Heart Association says people with pacemakers or implanted defibrillators should keep magnets at least 6 inches away and avoid magnetic mattress pads, ab stimulators and electronic body-fat scales.
- If you have nerve damage in your feet, the NIH warns you can burn them without feeling it, so skip heating pads and test water with a thermometer.
- Common medicines, from doxycycline to ibuprofen, plus the herb St. John’s wort, can make skin react badly to sunlight and UV light.
- Flashing light at 3 to 60 flashes per second can trigger seizures in people with photosensitive epilepsy, so check the flash rate on any device that flickers.
- Under its January 2026 policy, the FDA does not plan to check whether low-risk wellness products follow labeling rules, so you are the one who has to read the warnings page.
In May 2021, the Food and Drug Administration posted an unusual notice about phones and smartwatches1. Some contain magnets strong enough to switch a pacemaker or implanted defibrillator into “magnet mode,” which pauses its normal work. The FDA tested some of these products and confirmed it1.
Doctors use magnet mode on purpose during procedures. Outside the clinic, a defibrillator in magnet mode may miss a dangerously fast heartbeat, and a pacemaker may switch to pacing at a fixed rate1.
The agency judged the danger to patients to be low, and at the time it had no reports of anyone being harmed1. But the lesson reaches past phones. Magnetic bracelets, magnetic mattress pads, ab stimulators and body-fat scales all appear on the American Heart Association’s list of things to keep away from or avoid with an implanted heart device2.
Most wellness devices are low risk for most people. Yet the same short list of exceptions shows up across very different products: implanted electronics, numb skin, pregnancy, certain medicines and herbs, light-triggered seizures and blood clots. This guide gathers them in one place.
Many wellness devices reach you with no one checking the warnings
Under guidance updated on January 6, 2026, the FDA treats a product as a low-risk general wellness product if it is meant only for general wellness and poses low risk to users3. For those products, the FDA’s device center does not plan to check compliance with rules on labeling, registration or reporting injuries3.
So the warnings page on a “wellness” massage gun or light panel was written by the maker, and nobody at the agency has to approve it.
The FDA does draw lines. It says a skin-rejuvenating laser is not low risk because it can burn skin and eyes, and neither is a brain stimulator claiming to improve memory3. Devices cleared for a medical use get more review, as our buyer’s map to wellness devices explains.
Implanted heart devices: magnets and current are the concern
If you have a pacemaker or an implantable cardioverter-defibrillator (ICD), a device that shocks the heart out of a deadly rhythm, two things matter most: strong magnets and electricity passed through your body.
The American Heart Association advises, on its page last reviewed in October 20242:
- Magnets: Keep them at least 6 inches from the implant. In an ICD, a magnet can disable the lifesaving shock. Don’t wear magnetic bracelets or necklaces close to the implant.
- Magnetic bedding: Skip magnetic pillows and mattress pads, which some adjustable or smart beds include.
- Ab stimulators and electronic body-fat scales: The AHA says both are likely to interfere and should be avoided.
- TENS units: These small units send mild current through skin pads to ease pain. They may be acceptable with an ICD if you take precautions, but the pads shouldn’t go on your torso.
- Diathermy: One type of this deep-heat treatment, used in some physical therapy clinics, can permanently damage the device. Consult your heart team first.
Some surprises run the other way. The AHA lists massage chairs and pads, heating pads, handheld back massagers, hot tubs and tanning beds as posing little or no known risk to the implant itself, with motors kept at least 6 inches away2.
But “little risk to the implant” is not “safe for your heart.” Heat still strains the heart, as our sauna article explains. And a PEMF (pulsed electromagnetic field) mat uses changing magnetic fields, so ask your device clinic before lying on one.
The AHA also advises carrying your device ID card and telling every health professional about your implant, including dentists and imaging technicians2. It makes sense to tell massage and physical therapists, too.
Heat is a dose, and some bodies can’t feel it or shed it
Saunas, hot tubs, infrared mats, heating pads and foot spas ask your body to sense warmth and cool itself. Three groups have trouble with one or both.
People with nerve damage. Diabetes can dull feeling in the feet. The National Institute of Diabetes and Digestive and Kidney Diseases warns that people with this nerve damage can burn their feet without realizing it6. It advises against heating pads and hot water bottles on the feet, and suggests testing the water you wash your feet in with a thermometer: 90°F to 95°F is safe6. Apply the same logic to any heated mat or foot bath.
People taking certain medicines. In September 2025, the Centers for Disease Control and Prevention listed drug classes that can weaken heat tolerance7. Examples:
- Water pills (diuretics) such as furosemide can dehydrate you and upset your electrolytes.
- Beta blockers such as metoprolol reduce sweating and blood flow to the skin.
- Sedating antihistamines such as diphenhydramine reduce sweating.
- Antipsychotics, tricyclic antidepressants and the seizure drug topiramate can impair cooling.
- Lithium can become toxic when you’re dehydrated, and stimulants such as amphetamine raise body temperature.
The CDC notes the list isn’t complete7. A pharmacist can check yours.
People who are pregnant. The CDC says pregnancy can make heat illness more likely and can bring it on sooner. It adds that high body temperature and fever during pregnancy have, in some cases, been tied to birth defects and other problems8. Ask your prenatal provider before using a sauna or hot tub.
Light: what’s in your pill bottle, and how fast it flashes
Medicines and herbs. The FDA describes two kinds of drug-related light sensitivity9. A phototoxic reaction is skin irritation, often like a sunburn, that can appear within hours. A photoallergic reaction is an allergic rash that may take several days.
The FDA’s list of drugs that can cause them is long. It includes the antibiotics doxycycline and ciprofloxacin, antihistamines such as cetirizine, statins, water pills, ibuprofen and naproxen, birth control pills and the acne drug isotretinoin9. Not everyone who takes them reacts9.
Herbs belong on the list too. The NIH’s National Center for Complementary and Integrative Health says St. John’s wort, taken in large doses or put on the skin, might cause severe skin reactions in sunlight10. It also weakens many drugs, including birth control pills and warfarin10.
What about a red-light panel? The FDA’s warnings concern sunlight and ultraviolet light, including tanning beds9. We found no research testing these reactions under red or near-infrared panels, so treat it as an open question. Ask your pharmacist first, and start with a short session.
Flashing light and seizures. The Epilepsy Society, a British charity, says about 3% of people with epilepsy are photosensitive11. Flashing at 3 to 60 times per second can trigger a seizure, and 16 to 25 flashes per second is the most likely range11.
If a meditation goggle or brain-training gadget flickers, find out its flash rate. Anything between 3 and 60 per second sits inside that trigger range, so anyone with epilepsy should ask a neurologist first.
Caught off guard by flashing? The charity advises putting a hand fully over one eye and looking away11.
Massage guns and vibration: protect clots and fragile tissue
Hands-on massage is low risk for most people, according to NCCIH12. But the center notes rare serious harms: a blood clot, nerve injury or a broken bone. Some of the reported cases involved vigorous massage, like deep tissue work, or people at higher risk, such as older adults12.
A massage gun or vibration plate delivers strong, repeated force. So never pound or vibrate a leg that is newly swollen, tender and painful. Those are signs of deep vein thrombosis (DVT), a clot in a deep vein, says the National Heart, Lung, and Blood Institute13.
A clot that travels to the lungs, called a pulmonary embolism, causes shortness of breath and pain when you breathe. Call your provider right away about DVT symptoms13.
If you take a blood thinner, bruise easily, have thin bones or are in cancer treatment, ask before using strong percussion. People with cancer may need lighter pressure in sensitive areas12.
A master table: who should check before using what
“Ask first” means talk with the clinician who knows your condition before your first session. Your manual may add more. Our device-by-device articles cover whether each one works.
| Device | Ask first or skip if you… | Why | Source |
|---|---|---|---|
| Magnetic bracelets, pillows, mattress pads | Have a pacemaker or ICD | Magnets can trigger magnet mode; in an ICD, they can disable shocks | 12 |
| PEMF mats | Have a pacemaker, ICD or other implant | They use magnetic fields; AHA advises avoiding magnetic pads | 2 |
| TENS units | Have an ICD or pacemaker, are pregnant, or want pads on the head, neck or chest | AHA says not on the torso; one cleared TENS label rules out pregnancy and advises against use with demand pacemakers | 25 |
| Ab stimulator belts, body-fat scales | Have an implanted heart device | Likely to interfere; AHA says avoid | 2 |
| Heating pads, heated mats, foot spas | Have numb feet or nerve damage | You can burn without feeling it | 6 |
| Saunas, hot tubs, infrared cabins | Are pregnant, or take diuretics, beta blockers, sedating antihistamines, lithium or stimulants | Heat illness comes sooner in pregnancy; some drugs weaken cooling | 78 |
| Red-light and LED devices | Take light-sensitizing drugs or St. John’s wort | Skin reactions are documented with sunlight and UV; red light untested | 910 |
| Flashing light goggles or gadgets | Have epilepsy or a family member with it | 3 to 60 flashes per second can trigger seizures | 11 |
| Massage guns, vibration plates | Have a swollen, painful leg, take blood thinners, or have fragile bones | Rare clots and fractures are reported with vigorous massage | 1213 |
| Cold plunges | Have heart rhythm problems or Raynaud’s | Covered in our cold plunge article | — |
How solid is each warning?
| Warning | Evidence level | What it rests on |
|---|---|---|
| Strong magnets switch implanted heart devices into magnet mode | A built-in feature, confirmed by FDA tests with consumer magnets1 | |
| Phone and watch magnets have injured people with implants | FDA knew of no injuries in 20211 | |
| Heating pads are safe on numb feet | NIH warns of burns people don’t feel6 | |
| Getting overheated is harmless in pregnancy | CDC links high temperature and fever to birth defects in some cases8 | |
| Some drugs and St. John’s wort cause sun reactions | FDA and NCCIH910 | |
| Red-light panels trigger those reactions | Our search found no studies; FDA’s warnings cover sunlight and UV9 | |
| Flicker at 3 to 60 per second triggers seizures in photosensitive epilepsy | Epilepsy Society11 | |
| Massage or vibration dislodges clots | Rare reports; size of risk unknown12 |
How to read the warnings page in a manual
The warnings page is worth five minutes, especially because a wellness product’s label may never have been reviewed by the FDA3.
A real example shows how specific these pages get. In 2005, the FDA cleared a prescription TENS unit called E-Stim II. Its labeling said not to use it across the head, over the carotid sinus in the neck, or during pregnancy. It also said the unit was not recommended for people with demand pacemakers, because the current can block their output5.
It also warned that pads across the neck or mouth could cause throat spasms severe enough to close the airway. And it noted that blocking pain can hide a warning sign of a worsening problem5.
When you read a manual, look for:
- Placement rules. Where must pads, heads or panels never go?
- Time and intensity limits. A maximum session length is a safety limit, not a suggestion.
- Named conditions. Search for implants, pregnancy, diabetes, epilepsy, clots and cancer.
- What’s missing. A manual with no warnings at all calls for more caution, not less.
Before your first session: a checklist and a script
Run through this list for each new device, and again if your health or medicines change.
- Do I have anything implanted? A pacemaker, ICD, nerve stimulator or pump means a call to the clinic that manages it12.
- Does it use a magnet, a current or flashing light? Those features drive most implant and seizure cautions211.
- Can I feel heat and pressure normally there? If not, use a thermometer, a timer and low settings6.
- Am I pregnant? Ask before any heat device8.
- What do I take? Check prescriptions, over-the-counter drugs and herbs against the heat and light lists7910.
- Is any area swollen, painful or newly injured? Keep percussion away and get it checked13.
- Am I on the contraindications page? Then don’t use the device4.
- Do I know the stop signs? Stop for chest pain, fainting, trouble breathing, a seizure or a blistering burn. Call 911 for the first four.
Not sure how to ask? Try this with your pharmacist:
“I’m thinking about using a [device] for about [minutes], [times] a week. I take [medicines and supplements], and I have [conditions or implants]. Does anything here make this risky?”
Many natural-health readers believe a remedy should fit the person. Devices are no different. Knowing your own exceptions is part of listening to your body, and it lets you enjoy warmth, light and touch with fewer surprises.
When something goes wrong: report it, and read other reports
The FDA’s MAUDE database collects reports of device problems from makers, hospitals and the public. It’s updated monthly and holds about 10 years of reports14. On the MAUDE search page, you can enter a brand name or product code.
Read results with care. The FDA says these reports can’t show how often problems happen, and a report alone doesn’t prove the device caused the harm14. Many problems are never reported14. Use MAUDE to learn what has gone wrong, not to rank brands.
If you’re hurt, report it to the FDA’s MedWatch program online, on consumer Form FDA 3500B, or at 1-888-INFO-FDA (1-888-463-6332)15. Your clinician isn’t required to report for you, so file it yourself if needed15.
If an ad promised something the device couldn’t do, tell the Federal Trade Commission at ReportFraud.ftc.gov.
Questions readers ask
My device says “FDA registered.” Does that mean its warnings were reviewed?
No. Under its 2026 wellness policy, the FDA doesn’t plan to check whether low-risk wellness products follow labeling rules at all3. A cleared device has more review behind it, but you still need to read its contraindications.
Can I use a massage chair with a pacemaker?
The American Heart Association lists massage chairs and pads as posing little or no known risk to pacemakers and ICDs, with motors kept at least 6 inches away2. Check with your device clinic if you feel anything unusual, and avoid chairs with built-in magnets.
I take an antibiotic like doxycycline. Should I skip my sauna and red-light session?
Doxycycline is on the FDA’s list of drugs that can make skin react to sun and UV9. We found no research on red-light panels and these drugs, so ask your pharmacist before your session and keep it short. Heat is a separate question; check your other medicines against the CDC’s list7.
The bottom line
Most wellness devices are low risk for most people, and many of their manuals are never checked by a regulator. A short list of exceptions does most of the harm: implanted heart devices near magnets or current, numb skin under heat, pregnancy and overheating, light-sensitizing medicines and herbs, flashing light with epilepsy, and pressure on a possible blood clot.
Before you plug anything in, read the contraindications, run the checklist and ask a pharmacist about your medicines. If something goes wrong, stop, get care, and report it to the FDA so the next person has better information.
Related reading
About this article
This article was researched using U.S. government guidance, device labeling records and health organization sources, listed below, and was reviewed in October 2026. It is general education, not medical, legal or financial advice..
Sources
- U.S. Food and Drug Administration. “Magnets in Cell Phones and Smart Watches May Affect Pacemakers and Other Implanted Medical Devices.” FDA, 2021. fda.gov
- American Heart Association. “Devices That May Interfere With ICDs and Pacemakers.” AHA, 2024. heart.org
- U.S. Food and Drug Administration. “General Wellness: Policy for Low Risk Devices.” FDA guidance, 2026. fda.gov
- U.S. Food and Drug Administration. “Device Labeling Guidance #G91-1 (Blue Book Memo).” FDA, 1991. fda.gov
- U.S. Food and Drug Administration. “510(k) K050435: E-Stim II Transcutaneous Electrical Nerve Stimulator.” FDA, 2005. accessdata.fda.gov
- National Institute of Diabetes and Digestive and Kidney Diseases. “Diabetes & Foot Problems.” National Institutes of Health, 2017. niddk.nih.gov
- Centers for Disease Control and Prevention. “Heat and Medications – Guidance for Clinicians.” CDC, 2025. cdc.gov
- Centers for Disease Control and Prevention. “Heat and Pregnancy.” CDC, 2024. cdc.gov
- U.S. Food and Drug Administration. “The Sun and Your Medicine.” FDA. fda.gov
- National Center for Complementary and Integrative Health. “St. John’s Wort.” National Institutes of Health, 2025. nccih.nih.gov
- Epilepsy Society. “Photosensitive Epilepsy.” Epilepsy Society, 2025. epilepsysociety.org.uk
- National Center for Complementary and Integrative Health. “Massage Therapy: What You Need To Know.” National Institutes of Health, 2019. nccih.nih.gov
- National Heart, Lung, and Blood Institute. “Venous Thromboembolism: Symptoms.” National Institutes of Health, 2022. nhlbi.nih.gov
- U.S. Food and Drug Administration. “About Manufacturer and User Facility Device Experience (MAUDE).” FDA. fda.gov
- U.S. Food and Drug Administration. “Reporting Serious Problems to FDA.” FDA MedWatch. fda.gov